transformer solutions,mobile power transformer | Yawei Transformer

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Rated Capacity
Rated Voltage
Country
Message
0/1000

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Rated Capacity
Rated Voltage
Country
Message
0/1000

Vehicle Mounted Transformer

The vehicle-mounted mobile transformer is a flexible operation mode for substations and is a substation product developed to meet special power demands.

It is mainly used in the following occasions

We are a professional manufacturer of power transformers and a supplier of high-voltage electrical equipment.

 

Temporary substation

In areas where the demand for electricity is growing rapidly and exceeds the pre-planned power construction, it is put into operation as a temporary substation to alleviate the tight situation of power supply. It is put into operation as a temporary substation or leased to users when the construction plan of a permanent substation in a certain area is suspended due to a shortage of funds or for some reason.

Expansion and renovation of existing substations

During the maintenance of substation equipment or the expansion and renovation of substations, due to the high reliability requirements for power supply and the short-term substitution when power supply cannot be stopped.

Disaster Emergency response

When power outages are caused by weather conditions, natural disasters or other external factors, mobile substations can fully or partially replace a conventional substation, quickly restore power supply to users, and minimize the duration of power supply disruptions to the greatest extent.

Company Advantages

  • yawei.jpg

    JiangsuYawei transtormers have been successtuly exported to severa countries incuding the United Stotes, Canada, Panama, Venezuela, Uzbekistan,Australia,and Bulgaria.

    We have sufficient production capacity to ensure that goods can be delivered on time. We have professional after-sales teams around the world, this ensures prompt trouble shooting and resolution of any issues you may encounter.

  • yawei Cooperation.jpg

    Whether you are a utlity company, transformer distributor, or builder, you can purchase JiangsuYawei's power transformer with confidence,knowing that you are investing in a reliable and reputabe product.Experience the efficiency and reliablity of JiangsuYawei Transtormer tailored to meet your specific needs.

Parameters

SN Name Model
Primary electrical equipment
1 Power transformer SF5000/110115 ±2x2.5%36.5KVUd=10.5% YN.d11 ONAF uses 45# transformer oil
2 Neutral point complete set of grounding equipment GW13-72.5 630A discharge gap 120±5mm MCT 100-300/1A 10P20 30VA lightning arrester YH1.5VV5-72/186
3 110KVHGIS combined electrical apparatus 126KV 2000A 40kA current transformer, circuit breaker, isolation switch, grounding switch, bushing, etc.
4 110kV voltage transformer TYD-110/3-0.01H110/V3 0.1/V3 0.1/V3 0.1kV0.2/0.5/3P 20VA 30VA 5OVA
5 110KV zinc oxide arrester YH10WZ-108/281Ur-88kV In=10kA with a discharge counter
6 35kV incoming and outgoing line cabinet 40.5kV circuit breaker cabinet with 1250A-31.5kA incoming line from top to bottom
7 35kV busbar equipment cabinet PT is equipped with a 0.5A fuse and a bottom-plug lightning arrester with primary harmonic elimination
8 35kV substation transformer cabinet It varies by 30KVA 1A fuse
Secondary electrical equipment
1 Power transformer protection measurement and control panel Two main and rear integrated protection devices, one high-voltage measurement and control device, one low-voltage measurement and control device, one body protection device, and one public measurement and control device
2 Monitoring and remote control cabinet One set of remote control main unit (dual main and rear units), one set of planning and conversion device, two sets of monitoring main units (equipped with integrated automation and five-prevention), one set of switch, one set of time synchronization device, and one set of electrical acquisition device
3 Ac/DC power supply screen Dc power supply 3*10A/220VUPS power supply 2kVA
4 Battery screen 50AH DC220V
5 Multifunctional watch Grade 0.5
6 Multifunctional watch 0.2S
Auxiliary equipment
1 Semi-trailer The three-line six-axle suspension system has a load capacity greater than 75 tons, including the gooseneck, suspension and support systems. Meet the passability requirements of Class IV roads
2 Cabin Integrated fire alarm, air conditioning, lighting, electric heating, etc. are used to install indoor equipment such as secondary screen cabinets and switch cabinets
3 Online monitoring of transportation status Acceleration tester, GPS positioning instrument, forward and reverse dash CAM
4 SF6 automatic gas charging and venting device Pressure condensing type, SF6 hermetic compressor. Inflation rate >40kg/h 6-10 m ³ /H, compressor recovery rate 40kgh(8 m ³ /H)
5 Hold the hand and step onto the ladder when boarding the vehicle The supplier guarantees to meet the operational requirements, and the trolley ladder is self-retracting.

Applications

Utilities today seek to create and connect new sources of power generation to meet growing global demand, while also managing grid reliability, costs and regulatory factors.
  • Industrial Field.jpg

    Industrial Field

  • Petrochemical Industry.jpg

    Petrochemical Industry

  • Power System.jpg

    Power System

  • Transportation.jpg

    Transportation

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Rated Capacity
Rated Voltage
Country
Message
0/1000

Certificate

vehicle mounted transformer112-0
vehicle mounted transformer112-1
vehicle mounted transformer112-2
vehicle mounted transformer112-3
vehicle mounted transformer112-4

We are working around the world

Transformers (main transformer, single-phase transformer, pad mounted transformer, distribution transformer,mobile substation, transformer tank, radiator, electromagnetic wire)

image

Yoshlik transformers of Uzbekistan

Uzbekistan, as an important energy hub country in Central Asia, is undergoing modernization transformation and integration of renewable energy in its power system.

image

Uzbekistan General Contracting Installation

Uzbekistan, as one of the most populous and fastest-growing industrialized countries in Central Asia, is accelerating the realization of its energy self-sufficiency.

image

Tajikistan General Contracting Installation

As one of the countries with the richest hydropower resources in Central Asia, Tajikistan is promoting economic transformation and energy export strategies by upgrading power infrastructure.